SX-type
SP-type Inter-Connector consists of alternate layers of conductive and insulating rubber and of soft rubber insulators fitted on both sides. Since SP type has lower resistance than SS/SG, it is particularly ideal for display with tall height, such as LCD with backlight.
Outline Dimensions:

Dimensions and Tolerances:
Item | Unit | SX type | |
---|---|---|---|
Pitch | P | mm | 0.03±0.03/-0.01 |
Length | L | mm |
2.0~20.0±0.15
150.1~200.0±0.8 20.1~90.0±0.65% 200.1~300.0±1.0
90.1~150.0±0.6 |
Height | H | mm |
1.5~5.0±0.1
5.1~20.0+0.15/-0.1
|
Width | W | mm |
1.5±0.1
2.0±0.1 2.5±0.15 3.0±0.15 3.5±0.15
4.0±0.15 4.5±0.15 5.0±0.15 |
Width of conductive layer | Z | mm | 0.7±0.05 |
*H≧W/2
Basic Properties:
Item | Component | Unit | SX-35°type |
---|---|---|---|
Shore hardness A | Insulator Conductor Edge insulation part (1) |
ISO7619 (type A) |
60~65 |
70~75 | |||
20~25 | |||
35~40 | |||
Compression set | * | % | 15~20 |
Volume resistivity | Insulator Conductor Edge insulation part |
Ω/cm | 1 x 1014 |
0.5 | |||
1 x 1011 | |||
Dielectric breakdown voltage | Insulator Edge insulation part |
kV/mm | 23~27 |
23~27 | |||
Insulation resistance (DC 500V) | * | MΩ | 1 x 103≦ |
Operating temperature range | ºC | -25~85 |
(1) The hardness of the support material has alternatives of 20° and 35°.
*The test is carried out with Shin-Etsu’s own method.
*The test is carried out with Shin-Etsu’s own method.
Compression Curves:


Note:
Every item or numerical value indicated herein is measured by Shin-Etsu and out of guarantee.
The quality of the connector, which has been already assembled, is out of guarantee.
Please make sure to see about the purpose/conditions of use and practice your own test. Industrial ownership like patent doesn’t guarantee the usage of the connector.
Every item or numerical value indicated herein is measured by Shin-Etsu and out of guarantee.
The quality of the connector, which has been already assembled, is out of guarantee.
Please make sure to see about the purpose/conditions of use and practice your own test. Industrial ownership like patent doesn’t guarantee the usage of the connector.